Why are two floor temperature sensors provided with the schluter ditra heat system.
Schluter floor temperature sensor.
After the curb is installed schluter kerdi waterproofing membrane is installed over the ditra heat system on the shower base and all other waterproofing steps must be completed.
In your scenario you would need 2 zones and 2 t stats.
Schluter.
Two ditra heat e hk heating cables can be connected and controlled by a single ditra heat e rt thermostat if the total current is less than 15 amps.
Floor temperature sensors may not be threaded through the same conduit as the cold lead.
Mark where the cold hot splice will be placed cut the ditra heat or ditra heat duo matting and insert the splice.
The thermostat features a 5 ma built in ground fault circuit interrupter gfci with indicator light and includes a floor temperature sensor.
Floor warming into service.
The icon blinks and the period number 1 blinks too.
One sensor is connected to the thermostat while the other is stored in the thermostat electrical box.
Then connect the wires of the floor temperature sensor at the indicated location behind the thermostat.
Although schluter will extend the warranty from 10 years to 15 years if you do the insulation resistance test.
The second sensor can be connected in case of damage to the first sensor without.
Test the floor temperature sensors using a multimeter to verify accuracy of the sensors.
Let s dive into the tests one by one.
An insulation resistance test is recommended but not required.
Replace the thermostat faceplate and tighten the screw at the bottom of the unit.
Floor temperature sensor test.
Reinstall the front part of the thermostat on the mounting base.
Set the multimeter for resistance at 10k ω 2 at room temperature and take a reading between the sensor leads.
If you have set the t stat to read ambient it ignores the floor sensor and adjust the floor using the rooms air temp.
The floor temperature sensor should not be installed inside the shower area rather on the bathroom floor.
Area rugs are not recommended over the ditra heat system.
Do not place furniture or mats over the floor temperature sensor as they could act as insulation and lower the temperature of the floor warming system therefore causing the floor to feel cooler.
Test 4 temperature sensor.
Both floor temperature sensors are installed within the tile assembly.
Schluter ditra heat e rt ditra heat e rt is programmable touchscreen thermostat that allows you control your electric floor warming system any way you want.
One 1 floor sensor.
The power heating cable and floor temperature sensor connections are now complete.